WiFi (BACnet/Modbus Protocol) Thermostats / Controllers / Humidistat
- Complete Configurable Control Parameters.
- AC 24V (CE Certified) / 110V(CE Certified) / 230V(CE Certified) +/-15% 50/60Hz.
- Advanced Proportional / Integral (PI) Control.
![]() ![]() ․Wi-Fi BACnet IP open protocol communication ․IEEE 802.11 b/g ․Web Server based Configuration to configure Wi-Fi parameters ․Suitable for 2-pipe or 4-pipe Fan-coil HVAC system of On/Off controls. ․Effective run time accumulation for system reading/ resetting ․The 1- to 3-fan speed can be operated in the mode of auto changeover or manual selected continuous mode. ․Room temperature or setpoint temperature selectable for normal display ․Cool, heat, or both auto/ manual changeover with adjustable zero energy band ․Full configurable parameters such as switching differential, cycle time, and etc. ․Proportional plus integral (PI) algorithm applied to on/off control ․Optional Remote sensor (RS) input interface for connecting to remote temperature sensor ․Optional Energy Saving input (ESI) interface for connecting to hotel card key , occupied/unoccupied sensor or lighting interlock signal ․Optional extra digital input (DI) interface for connecting to hotel window/door open detection contact for energy saving control ․Adjustable unoccupied setpoints for energy saving ․Optional settable countdown Timer (0 to 24 hours) function to stop control output when time expires ․Optional sleep mode function for raising temperature setpoint in 2 hours when enable ․Non-volatile memory (EEPROM) retains user settings during power loss ․Each button and Energy Saving lockable ․oC or oF display, no fluctuation sensing algorithm ․Control off output when system at “OFF” status | ![]() ![]() ․Wi-Fi Modbus TCP/IP open protocol communication ․IEEE 802.11 b/g ․Web Server based Configuration to configure the Wi-Fi module ․Suitable for 2-pipe or 4-pipe Fan-coil HVAC system of On/Off controls. ․Effective run time accumulation for system reading/resetting ․The 1- to 3-fan speed can be operated in the mode of auto changeover or manual selected continuous mode. ․Room temperature or setpoint temperature selectable for normal display ․Cool, heat, or both auto/ manual changeover with adjustable zero energy band ․Full configurable parameters such as switching differential, cycle time, and etc. ․Proportional plus integral (PI) algorithm applied to on/off control ․Optional Remote sensor (RS) input interface for connecting to remote temperature sensor ․Optional Energy Saving input (ESI) interface for connecting to hotel card key , occupied/unoccupied sensor or lighting interlock signal ․Optional extra digital input (DI) interface for connecting to hotel window/door open detection contact for energy saving control ․Adjustable unoccupied setpoints for energy saving ․Optional settable countdown Timer (0 to 24 hours) function to stop control output when time expires ․Optional sleep mode function for raising temperature setpoint in 2 hours when enable ․Non-volatile memory (EEPROM) retains user settings during power loss ․Each button and Energy Saving lockable ․oC or oF display, no fluctuation sensing algorithm ․Control off output when system at “OFF” status |
![]() ![]() ․Wi-Fi Modbus TCP/ IP open protocol communication ․IEEE 802.11 b/g ․Web Server based Configuration to configure the Wi-Fi module ․Suitable for 2-pipe or 4-pipe Fan-coil, AHUs, heat pumps, and other HVAC system of On/Off controls ․Effective run time accumulation for system reading/resetting ․Optional 1- to 3- fan speed can be operated in the mode of auto changeover or manual selected continuous mode. ․Cool, heat, or both auto/ manual changeover with adjustable zero energy band ․Full configurable parameters such as switching differential, cycle time, and etc. ․Proportional plus integral (PI) algorithm applied to on/off control ․Optional Wall Setter ․Optional Remote sensor (RS) input interface for connecting to remote temperature sensor ․Selectable temperature sensor input from wall setter or RS interface ․Optional energy saving input (ESI) interface for room occupied/unoccupied detection device ․Optional one extra digital input interfaces for window or door open/close detection device ․Adjustable unoccupied setpoints for heating and cooling mode control ․Optional settable countdown Timer (0 to 24 hours) function to stop control outputs when time expires ․Optional sleep mode function for raising 2 ℃ temperature setpoint in 2 hours ․Non-volatile memory (EEPROM) retains user settings during power loss ․Control off output when system at “OFF” status ․Maximum and minimum set-point limits settable | ![]() ![]() ․Pre-set a whole week, 5-2, 5-1-1, or 7 day program that can be separate or whole week programmed for weekday and weekend with 4 schedules and 4 timers each ․12- or 24- hour format with battery backed day and time ․Wi-Fi Modbus TCP/IP open protocol communication ․IEEE 802.11 b/g ․Web Server based Configuration to configure the Wi-Fi module or works as Access Point ․Suitable for 2-pipe or 4-pipe Fan-coil HVAC system of On/Off controls ․Effective run time accumulation for system reading/resetting ․Optional 1- to 3- fan speed can be operated in the mode of auto changeover or manual selected continuous mode. ․Cool, heat, or both auto/ manual changeover with adjustable zero energy band ․Full configurable parameters such as switching differential, cycle time, and etc. ․Proportional plus integral (PI) algorithm applied to on/off control ․Optional WBS092 series slave Wall Setter ․Get a temperature from wall Setter for control and get a temperature from NTC10K ohm sensor for monitor ․An remote sensor (RS) input interface for connecting to NTC10K remote temperature sensor ․Optional energy saving input (ESI) interface for room occupied/unoccupied detection device ․Optional one extra digital input interfaces for window or door open/close detection device ․Adjustable unoccupied setpoints for heating and cooling mode control ․Optional sleep mode function for raising 2 ℃ temperature setpoint in 2 hours ․Non-volatile memory (EEPROM) retains user settings during power loss |
![]() ![]() ․Wi-Fi Modbus TCP/IP open protocol communication ․IEEE 802.11 b/g ․Web Server based Configuration to configure the Wi-Fi module or Works as Access Point ․Suitable for 2-pipe or 4-pipe Fan-coil HVAC system of On/Off controls. ․The 1- to 3-fan speed can be operated in the mode of auto changeover or manual selected continuous mode. ․Room temperature or setpoint temperature selectable for normal display ․Cool, heat, or both auto/ manual changeover with adjustable zero energy band ․Full configurable parameters such as switching differential, cycle time, and etc. ․Proportional plus integral (PI) algorithm applied to on/off control ․Optional Remote sensor (RS) input interface for connecting to remote temperature sensor ․Optional Energy Saving input (ESI) interface for connecting to hotel card key , occupied/unoccupied sensor or lighting interlock signal ․Optional extra digital input (DI) interface for connecting to hotel window/door open detection contact for energy saving control ․Adjustable unoccupied setpoints for heating and cooling mode control ․Optional settable countdown Timer (0 to 24 hours) function to stop control output when time expires ․Optional sleep mode function for raising t emperature setpoint in 2 hours when enable ․Non-volatile memory (EEPROM) retains user settings during power loss ․Each button and Energy Saving lockable ․oC or oF and relative humidity (%RH) displays ․Control off output when system at “OFF” status Wish you buy UK cheap rolex replica watches from the discounted website. They are suitable for both men and women. If you like forever classic fake watches, you cannot miss the best replica breitling watches UK. Best UK fake watches online are worth having. |
![]() ![]() ․Wi-Fi Modbus TCP/IP open protocol communication ․IEEE 802.11 b/g ․Web Server based Configuration to configure the Wi-Fi module ․Effective run time accumulation for system reading/resetting ․The fan speed can be operated in the mode of auto changeover or manual selected continuous mode. ․Room temperature or setpoint temperature selectable for normal display ․Full configurable parameters such as switching differential, cycle time, and etc. ․Proportional plus integral (PI) algorithm applied to modulating control and/or floating control ․0(2) to 10 Vdc or 10 to 0(2) Vdc control signal output selectable for direct / reverse acting output ․Optional multi-stage on/off control outputs ․Minimum Cycle/ On/ Off time settable ․Optional Remote sensor (RS) input interface for connecting to remote temperature sensor ․Optional Energy Saving input (ESI) interface for connecting to hotel card key , occupied/unoccupied sensor or lighting interlock signal ․Optional extra digital input for Window/ Door open detection to save energy ․Adjustable unoccupied setpoints for heating and cooling mode control ․Optional settable countdown Timer (0 to 24 hours) function to stop control output when time expires ․Optional sleep mode function for raising 2℃ temperature setpoint in 2 hours ․Non-volatile memory (EEPROM) retains user settings during power loss ․User’s buttons and Energy Saving lockable ․oC or oF display, no fluctuation sensing algorithm ․Control off output when system at “OFF” status | ![]() ![]() ․Wi-Fi Modbus TCP/ IP open protocol communication ․IEEE 802.11 b/g ․Web Server based Configuration to configure the Wi-Fi module ․Suitable for 2-pipe or 4-pipe Fan-coil, AHUs, heat pumps, and other HVAC system of On/Off controls ․Effective run time accumulation for system reading/resetting ․Optional 1- to 3- fan speed can be operated in the mode of auto changeover or manual selected continuous mode. ․Cool, heat, or both auto/ manual changeover with adjustable zero energy band ․Full configurable parameters such as switching differential, cycle time, and etc. ․0(2) to 10 Vdc or 10 to 0(2) Vdc control signal output selectable for direct / reverse acting output ․Optional multi-stage on/off control outputs ․Optional Wall Setter ․Optional Remote sensor (RS) input interface for connecting to remote temperature sensor ․Selectable temperature sensor input from wall setter or RS interface ․Optional energy saving input (ESI) interface for room occupied/unoccupied detection device ․Optional one extra digital input interfaces for window or door open/close detection device ․Adjustable unoccupied setpoints for heating and cooling mode control ․Optional settable countdown Timer (0 to 24 hours) function to stop control outputs when time expires ․Optional sleep mode function for raising 2 ℃ temperature setpoint in 2 hours ․Non-volatile memory (EEPROM) retains user settings during power loss ․Control off output when system at “OFF” status ․Maximum and minimum set-point limits settable |
![]() ![]() ․Pre-set a whole week, 5-2, 5-1-1, or 7 day program that can be separate or whole week programmed for weekday and weekend with 4 schedules and 4 timers each ․12- or 24- hour format with battery backed day and time ․Wi-Fi Modbus TCP/ IP open protocol communication ․IEEE 802.11 b/g ․Web Server based Configuration to configure the Wi-Fi module or works as Access Point ․Suitable for 2-pipe or 4-pipe Fan-coil, AHUs, heat pumps, and other HVAC system of On/Off controls ․1- to 3- fan speed can be operated in auto mode or manual selected continuous mode. ․Cool, heat, or both auto/ manual changeover with adjustable zero energy band ․Full configurable parameters such as switching differential, cycle time, and etc. ․0(2) to 10 Vdc or 10 to 0(2) Vdc control signal output selectable for direct / reverse acting output ․Optional multi-stage on/off control outputs ․Optional Wall Setter ․Optional Remote sensor (RS) input interface for connecting to remote temperature sensor ․Selectable temperature sensor input from wall setter or RS interface ․Optional energy saving input (ESI) interface for room occupied/unoccupied detection device ․Optional one extra digital input interfaces for window or door open/close detection device ․Adjustable unoccupied setpoints for heating and cooling mode control ․Optional sleep mode function ․Non-volatile memory (EEPROM) retains user settings during power loss ․Control off output when system at “OFF” status | ![]() ![]() ․Wi-Fi BACnet IP open protocol communication ․IEEE 802.11 b/g ․Web Server based Configuration to configure Wi-Fi parameters ․Effective run time accumulation for system reading/ resetting ․The fan speed can be operated in the mode of auto changeover or manual selected continuous mode. ․Room temperature or setpoint temperature selectable for normal display ․Full configurable parameters such as switching differential, cycle time, and etc. ․Proportional plus integral (PI) algorithm applied to modulating control and/or floating control ․0(2) to 10 Vdc or 10 to 0(2) Vdc control signal output selectable for direct / reverse acting output ․Optional multi-stage on/off control outputs ․Minimum Cycle/ On/ Off time settable ․Optional Remote sensor (RS) input interface for connecting to remote temperature sensor ․Optional Energy Saving input (ESI) interface for connecting to hotel card key , occupied/unoccupied sensor or lighting interlock signal ․Optional extra digital input for Window/ Door open detection to save energy ․Adjustable unoccupied setpoints for heating and cooling mode control ․Optional settable countdown Timer (0 to 24 hours) function to stop control output when time expires ․Optional sleep mode function for raising 2℃temperature setpoint in 2 hours ․Non-volatile memory (EEPROM) retains user settings during power loss ․User’s buttons and Energy Saving lockable ․oC or oF display, no fluctuation sensing algorithm ․Control off output when system at “OFF” status |
![]() ![]() ․Wi-Fi Modbus TCP/IP open protocol communication ․IEEE 802.11 b/g ․Web Server based Configuration to configure the Wi-Fi module ․For 2-Pipe or with heater Fan-Coil Unit, AHUs, or pressure dependent VAVs application of floating control. ․Proportional plus integral (PI) algorithm applied to floating control for different stroke times ․The 1- to 3-fan speed can be operated in the mode of auto changeover or manual selected continuous mode. ․Full-fledged configurable parameters such as switching differential, cycle time, and etc to provide customized control requirements. ․Effective run time accumulation for system reading/resetting ․Room temperature or setpoint temperature selectable for normal display ․Optional Remote sensor (RS) input interface for connecting to remote temperature sensor ․Optional Energy Saving input (ESI) interface for connecting to hotel card key , occupied/unoccupied sensor or lighting interlock signal ․Optional extra digital input (DI) interface for connecting to hotel window/door open detection contact for energy saving control ․Adjustable unoccupied setpoints for heating and cooling mode control ․Optional settable countdown Timer (0 to 24 hours) function to stop control output when time expires ․Non-volatile memory (EEPROM) retains user settings during power loss ․Minimum open/ close and on/ off time adjustments ․User’s buttons and Energy Saving lockable ․oC or oF display, no fluctuation sensing algorithm ․Control off output when system at “OFF” status | ![]() ![]() ․Wi-Fi Modbus TCP/ IP open protocol communication ․IEEE 802.11 b/g ․Web Server based Configuration to configure the Wi-Fi module ․Suitable for 2-pipe or 4-pipe Fan-coil, AHUs, heat pumps, and other HVAC system of floating and/or on-off controls ․Effective run time accumulation for system reading/resetting ․Optional 1- to 3- fan speed can be operated in the mode of auto changeover or manual selected continuous mode. ․Cool, heat, or both auto/ manual changeover with adjustable zero energy band ․Full configurable parameters such as switching differential, cycle time, and etc. ․Proportional plus integral (PI) algorithm applied to on/off control ․Optional Wall Setter ․Optional Remote sensor (RS) input interface for connecting to remote temperature sensor ․Selectable temperature sensor input from wall setter or RS interface ․Optional energy saving input (ESI) interface for room occupied/unoccupied detection device ․Optional one extra digital input interfaces for window or door open/close detection device ․Adjustable unoccupied setpoints for heating and cooling mode control ․Optional settable countdown Timer (0 to 24 hours) function to stop control outputs when time expires ․Optional sleep mode function for raising 2 ℃ temperature setpoint in 2 hours ․Non-volatile memory (EEPROM) retains user settings during power loss ․Control off output when system at “OFF” status ․Maximum and minimum set-point limits settabl |
![]() ![]() ․Pre-set a whole week, 5-2, 5-1-1, or 7 day program that can be separate or whole week programmed for weekday and weekend with 4 schedules and 4 timers each ․12- or 24- hour format with battery backed day and time ․Wi-Fi Modbus TCP/ IP open protocol communication ․IEEE 802.11 b/g ․Web Server based Configuration to configure the Wi-Fi module or works as Access Point ․Suitable for 2-pipe or 4-pipe Fan-coil, AHUs, heat pumps, and other HVAC system of floating and/or on-off controls ․Optional 1- to 3- fan speed can be operated in the mode of auto changeover or manual selected continuous mode. ․Cool, heat, or both auto/ manual changeover with adjustable zero energy band ․Full configurable parameters such as switching differential, cycle time, and etc. ․Proportional plus integral (PI) algorithm applied to on/off control ․Optional Wall Setter ․Optional Remote sensor (RS) input interface for connecting to remote temperature sensor ․Selectable temperature sensor input from wall setter or RS interface ․Optional energy saving input (ESI) interface for room occupied/unoccupied detection device ․Optional one extra digital input interfaces for window or door open/close detection device ․Adjustable unoccupied setpoints for heating and cooling mode control ․Optional sleep mode function ․Non-volatile memory (EEPROM) retains user settings during power loss ․Control off output when system at “OFF” status | ![]() ![]() ․Wi-Fi BACnet IP open protocol communication ․IEEE 802.11 b/g ․Web Server based Configuration to configure Wi-Fi parameters ․For 2-Pipe or with heater Fan-Coil Unit, AHUs, or pressure dependent VAVs application of floating control. ․Proportional plus integral (PI) algorithm applied to floating control for different stroke times ․The 1- to 3-fan speed can be operated in the mode of auto changeover or manual selected continuous mode. ․Full-fledged configurable parameters such as switching differential, cycle time, and etc to provide customized control requirements. ․Effective run time accumulation for system reading/ resetting ․Room temperature or setpoint temperature selectable for normal display ․Optional Remote sensor (RS) input interface for connecting to remote temperature sensor ․Optional Energy Saving input (ESI) interface for connecting to hotel card key , occupied/unoccupied sensor or lighting interlock signal ․Optional extra digital input (DI) interface for connecting to hotel window/door open detection contact for energy saving control ․Adjustable unoccupied setpoints for heating and cooling mode control ․Optional settable countdown Timer (0 to 24 hours) function to stop control output when time expires ․Non-volatile memory (EEPROM) retains user settings during power loss ․Minimum open/ close and on/ off time adjustments ․User’s buttons and Energy Saving lockable ․oC or oF display, no fluctuation sensing algorithm ․Control off output when system at “OFF” status |
![]() ![]() ․Wi-Fi Modbus TCP/IP open protocol communication ․IEEE 802.11 b/g ․Web Server based Configuration to configure the Wi-Fi module or works as Access Point ․Suitable for single to multi-stage On/Off step control applications. ․Adjustable differential and stage band width algorithm applied to multi-stage step controls ․Adjustable minimum staging/ on/ off time ․Effective run time accumulation for system reading/resetting ․Room temperature digital display and user selected temperature setting on demand ․Full configurable parameters such as switching differential, cycle time, and etc. ․Optional Remote sensor (RS) input interface for connecting to remote temperature sensor ․Optional Energy Saving input (ESI) interface for connecting to hotel card key , occupied/unoccupied sensor or lighting interlock signal ․Optional extra digital input (DI) interface for connecting to hotel window/door open detection contact for energy saving control ․Adjustable unoccupied set-point for heating and cooling mode control ․1- to 3-fan speed can be operated in the mode of auto changeover or manual selected continuous mode. ․Optional settable countdown Timer (0 to 24 hours) function to turn off control output when time expires ․Optional sleep mode function for raising 2℃ setpoint temperature in 2 hours when enable ․Non-volatile memory (EEPROM) retains user settings during power loss ․User’s buttons and Energy Saving lockable ․oC or oF display, no fluctuation sensing algorithm ․Control off output when system at “OFF” status | ![]() ![]() ․Wi-Fi Modbus TCP/ IP open protocol communication ․IEEE 802.11 b/g ․Web Server based Configuration to configure the Wi-Fi module or Works as Access Point ․Suitable for Fan-coil, AHUs, heat pumps, and other HVAC system of multi-stage On/Off step controls ․Effective run time accumulation for system reading/resetting ․Optional 1- to 3- fan speed can be operated in the mode of auto changeover or manual selected continuous mode. ․Cool, heat, or both auto/ manual changeover with adjustable zero energy band ․Full configurable parameters such as switching differential, cycle time, and etc. ․Proportional plus integral (PI) algorithm applied to on/off control ․Optional Wall Setter ․Optional Remote sensor (RS) input interface for connecting to remote temperature sensor ․Selectable temperature sensor input from wall setter or RS interface ․Optional energy saving input (ESI) interface for room occupied/unoccupied detection device ․Optional one extra digital input interfaces for window or door open/close detection device ․Adjustable unoccupied setpoints for heating and cooling mode control ․Optional settable countdown Timer (0 to 24 hours) function to stop control outputs when time expires ․Optional sleep mode function for raising 2 ℃ temperature setpoint in 2 hours ․Non-volatile memory (EEPROM) retains user settings during power loss ․Control off output when system at “OFF” status ․Maximum and minimum set-point limits settable |
![]() ![]() ․Pre-set a whole week, 5-2, 5-1-1, or 7 day program that can be separate or whole week programmed for weekday and weekend with 4 schedules and 4 timers each ․12- or 24- hour format with battery backed day and time ․Wi-Fi Modbus TCP/ IP open protocol communication ․IEEE 802.11 b/g ․Web Server based Configuration to configure the Wi-Fi module or Works as Access Point ․Suitable for Fan-coil, AHUs, heat pumps, and other HVAC system of multi-stage On/Off step controls ․Optional 1- to 3- fan speed can be operated in the mode of auto changeover or manual selected continuous mode. ․Cool, heat, or both auto/ manual changeover with adjustable zero energy band ․Full configurable parameters such as switching differential, cycle time, and etc. ․Proportional plus integral (PI) algorithm applied to on/off control ․Optional Wall Setter ․Optional Remote sensor (RS) input interface for connecting to remote temperature sensor ․Selectable temperature sensor input from wall setter or RS interface ․Optional energy saving input (ESI) interface for room occupied/unoccupied detection device ․Optional one extra digital input interfaces for window or door open/close detection device ․Adjustable unoccupied setpoints for heating and cooling mode control ․Optional sleep mode function ․Non-volatile memory (EEPROM) retains user settings during power loss ․Control off output when system at “OFF” status | ![]() ![]() ․Wi-Fi BACnet IP open protocol communication ․IEEE 802.11 b/g ․Web Server based Configuration to configure Wi-Fi parameters ․Suitable for single to multi-stage On/Off step control applications. ․Adjustable differential and stage band width algorithm applied to multi-stage step controls ․Adjustable minimum staging/ on/ off time ․Effective run time accumulation for system reading/ resetting ․Room temperature digital display and user selected temperature setting on demand ․Full configurable parameters such as switching differential, cycle time, and etc. ․Optional Remote sensor (RS) input interface for connecting to remote temperature sensor ․Optional Energy Saving input (ESI) interface for connecting to hotel card key , occupied/unoccupied sensor or lighting interlock signal ․Optional extra digital input (DI) interface for connecting to hotel window/door open detection contact for energy saving control ․Adjustable unoccupied set-point for heating and cooling mode control ․1- to 3-fan speed can be operated in the mode of auto changeover or manual selected continuous mode. ․Optional settable countdown Timer (0 to 24 hours) function to turn off control output when time expires ․Optional sleep mode function for raising 2℃ setpoint temperature in 2 hours when enable ․Non-volatile memory (EEPROM) retains user settings during power loss ․User’s buttons and Energy Saving lockable ․oC or oF display, no fluctuation sensing algorithm ․Control off output when system at “OFF” status |
![]() ![]() ․Wi-Fi Modbus TCP/IP open protocol communication ․IEEE 802.11 b/g ․Web Server based Configuration to configure the Wi-Fi module or Works as Access Point ․Operator Interface for connecting to TCM-W series direct digital unitary controllers or others which need room temperature information and user settings ․Digital display of sensed zone temperature and temperature setting and controller status ․Push button operation for setting and commanding ․Built-in a NTC temperature sensor ․Graphical icon LCD display with optional LED backlight |
![]() ![]() ․Wi-Fi Modbus TCP/IP open protocol communication ․IEEE 802.11 b/g ․Web Server based Configuration to configure the Wi-Fi module or Works as Access Point ․Suitable for heat pump controls. ․Effective run time accumulation for system reading/resetting ․The 1- to 3-fan speed can be operated in the mode of auto changeover or manual selected continuous mode. ․Room temperature or setpoint temperature selectable for normal display ․Cooling and/or heating, auto/ manual changeover with adjustable zero energy band ․Full configurable parameters such as switching differential, cycle time, and etc. ․Optional Remote sensor (RS) input interface for connecting to remote temperature sensor ․Optional Energy Saving input (ESI) interface for connecting to hotel card key , occupied/unoccupied sensor or lighting interlock signal ․Optional extra digital input (DI) interface for connecting to hotel window/door open detection contact for energy saving control ․Adjustable unoccupied setpoints for heating and cooling mode control ․Optional settable countdown Timer (0 to 24 hours) function to stop control output when time expires ․Optional sleep mode function for raising temperature setpoint in 2 hours when enable ․Non-volatile memory (EEPROM) retains user settings during power loss ․Each button and Energy Saving lockable ․oC or oF display, no fluctuation sensing algorithm ․Control off output when system at “OFF” status ․Maximum and minimum set-point limits settable | ![]() ![]() ․Wi-Fi Modbus TCP/IP open protocol communication ․IEEE 802.11 b/g ․Web Server based Configuration to configure the Wi-Fi module or works as Access Point ․Optional 1- to 3- fan speed can be operated in the mode of auto changeover or manual selected continuous mode. ․Cool, heat, or both auto/ manual changeover with adjustable zero energy band ․Full configurable parameters such as switching differential, cycle time, and etc. ․Proportional plus integral (PI) algorithm applied to on/off control ․Optional Remote sensor (RS) input interface for connecting to remote temperature sensor ․Optional energy saving input (ESI) interface for room occupied/unoccupied detection device ․Optional Energy Saving input (ESI) interface for connecting to hotel card key , occupied/unoccupied sensor or lighting interlock signal ․Optional extra digital input (DI) interface for connecting to hotel window/door open detection contact for energy saving control ․Optional WDS092 wall setter ․Adjustable unoccupied setpoints for heating and cooling mode control ․Non-volatile memory (EEPROM) retains user settings during power loss ․Control off output when system at “OFF” status ․Maximum and minimum set-point limits settable |
![]() ![]() ․Wi-Fi Modbus TCP/IP open protocol communication ․IEEE 802.11 b/g ․Web Server based Configuration to configure the Wi-Fi module or works as Access Point ․Pre-set a whole week, 5-2, 5-1-1, or 7 day program that can be separate or whole week programmed for weekday and weekend with 4 schedules and 4timers each ․Optional 1- to 3- fan speed can be operated in the mode of auto changeover or manual selected continuous mode. ․Cool, heat, or both auto/ manual changeover with adjustable zero energy band ․Full configurable parameters such as switching differential, cycle time, and etc. ․Proportional plus integral (PI) algorithm applied to on/off control ․Optional Remote sensor (RS) input interface for connecting to remote temperature sensor ․Optional energy saving input (ESI) interface for room occupied/unoccupied detection device ․Optional Energy Saving input (ESI) interface for connecting to hotel card key , occupied/unoccupied sensor or lighting interlock signal ․Optional extra digital input (DI) interface for connecting to hotel window/door open detection contact for energy saving control ․Optional WDS092 wall setter ․Adjustable unoccupied setpoints for heating and cooling mode control ․Non-volatile memory (EEPROM) retains user settings during power loss ․Control off output when system at “OFF” status ․Maximum and minimum set-point limits settable |