- Complete Configurable Control Parameters.
- AC 24V (CE Certified) / 110V / 230V +/-15% 50/60Hz.
- Advanced Proportional / Integral (PI) Control.
TBN100-E Series-10/100 Base-T SNMP Full Configurable Digital Multi-stage Control Thermostats FEATURES ․10/100 Base-T SNMP V1,V2c,V3 open protocol communication ․Suitable for single to multi-stage On/Off step control applications. ․Adjustable differential and stage band width algorithm applied to multi-stage step controls ․Room temperature digital display and user selected temperature setting on demand ․Full configurable parameters such as switching differential, cycle time, and etc. ․Optional Remote sensor (RS) input interface for connecting to remote temperature sensor ․Optional Energy Saving input (ESI) interface for connecting to hotel card key , occupied/unoccupied sensor or lighting interlock signal ․Optional extra digital input (DI) interface for connecting to hotel window/door open detection contact for energy saving control ․Adjustable unoccupied set-point for heating and cooling mode control ․1- to 3-fan speed can be operated in the mode of auto changeover or manual selected continuous mode. ․Optional settable countdown Timer (0 to 24 hours) function to turn off control output when time expires ․Optional sleep mode function for raising 2℃ setpoint temperature in 2 hours when enable ․Non-volatile memory (EEPROM) retains user settings during power loss ․User’s buttons and Energy Saving lockable ․oC or oF display ․Control off output when system at “OFF” status | TCN100-E Series-10/100 Base-T SNMP Full Configurable Digital Multi-stage Control Temperature Controllers ․10/100 Base-T SNMP V1,V2c,V3 open protocol communication ․ Suitable for Fan-coil, AHUs, heat pumps, and other HVAC system of multi-stage On/Off step controls ․ Optional 1- to 3- fan speed can be operated in the mode of auto changeover or manual selected continuous mode. ․ Cool, heat, or both auto/ manual changeover with adjustable zero energy band ․ Full configurable parameters such as switching differential, cycle time, and etc. ․ Proportional plus integral (PI) algorithm applied to on/off control ․ Optional Wall Setter ․ Optional Remote sensor (RS) input interface for connecting to remote temperature sensor ․ Selectable temperature sensor input from wall setter or RS interface ․ Optional energy saving input (ESI) interface for room occupied/unoccupied detection device ․ Optional one extra digital input interfaces for window or door open/close detection device ․ Adjustable unoccupied setpoints for heating and cooling mode control ․ Optional settable countdown Timer (0 to 24 hours) function to stop control outputs when time expires ․ Optional sleep mode function for raising 2 ℃temperature setpoint in 2 hours ․ Non-volatile memory (EEPROM) retains user settings during power loss ․ Control off output when system at “OFF” status ․ Maximum and minimum set-point limits settable |