- Complete Configurable Control Parameters.
- AC 24V (CE Certified) / 110V / 230V +/-15% 50/60Hz.
- Advanced Proportional / Integral (PI) Control.
TBB400-H Series-BTL Certified BACnet® MS/TP Digital FCU Thermostats With Both Temperature and Humidity Displays ․BTL certified BACnet MS/ TP, RS-485 open protocol communication with complete baud rate selections ․Suitable for 2-pipe or 4-pipe Fan-coil HVAC system of On/Off controls. ․Effective run time accumulation for system reading/resetting ․The 1- to 3-fan speed can be operated in the mode of auto changeover or manual selected continuous mode. ․Room temperature or setpoint temperature selectable for normal display ․Cool, heat, or both auto/ manual changeover with adjustable zero energy band ․Full configurable parameters such as switching differential, cycle time, and etc. ․Proportional plus integral (PI) algorithm applied to on/off control ․Optional Remote sensor (RS) input interface for connecting to remote temperature sensor ․Optional Energy Saving input (ESI) interface for connecting to hotel card key , occupied/unoccupied sensor or lighting interlock signal ․Optional extra digital input (DI) interface for connecting to hotel window/door open detection contact for energy saving control ․Adjustable unoccupied setpoints for heating and cooling mode control ․Optional settable countdown Timer (0 to 24 hours) function to stop control output when time expires ․Optional sleep mode function for raising temperature setpoint in 2 hours when enable ․Non-volatile memory (EEPROM) retains user settings during power loss ․Each button and Energy Saving lockable ․oC or oF and relative humidity (%RH) displays ․Control off output when system at “OFF” status ․Maximum and minimum set-point limits settable | TBM400-H Series-Modbus Full Configurable Digital FCU Thermostats With Both Temperature and Humidity Displays ․RS-485 Modbus/ RTU open protocol communication with complete baud rate and parity selections ․Suitable for 2-pipe or 4-pipe Fan-coil HVAC system of On/Off controls. ․Effective run time accumulation for system reading/resetting ․The 1- to 3-fan speed can be operated in the mode of auto changeover or manual selected continuous mode. ․Room temperature or setpoint temperature selectable for normal display ․Cool, heat, or both auto/ manual changeover with adjustable zero energy band ․Full configurable parameters such as switching differential, cycle time, and etc. ․Proportional plus integral (PI) algorithm applied to on/off control ․Optional Remote sensor (RS) input interface for connecting to remote temperature sensor ․Optional Energy Saving input (ESI) interface for connecting to hotel card key , occupied/unoccupied sensor or lighting interlock signal ․Optional extra digital input (DI) interface for connecting to hotel window/door open detection contact for energy saving control ․Adjustable unoccupied setpoints for heating and cooling mode control ․Optional settable countdown Timer (0 to 24 hours) function to stop control output when time expires ․Optional sleep mode function for raising temperature setpoint in 2 hours when enable ․Non-volatile memory (EEPROM) retains user settings during power loss ․Each button and Energy Saving lockable ․oC or oF and relative humidity (%RH) displays ․Control off output when system at “OFF” status ․Maximum and minimum set-point limits settable |
TBS400-H Series-Full Configurable Digital FCU Thermostats With Both Temperature and Humidity Displays ․Suitable for 2-pipe or 4-pipe Fan-coil HVAC system of On/Off controls. ․The 1- to 3-fan speed can be operated in the mode of auto changeover or manual selected continuous mode. ․Room temperature or setpoint temperature selectable for normal display ․Cool, heat, or both auto/ manual changeover with adjustable zero energy band ․Full configurable parameters such as switching differential, cycle time, and etc. ․Proportional plus integral (PI) algorithm applied to on/off control ․Optional Remote sensor (RS) input interface for connecting to remote temperature sensor ․Optional Energy Saving input (ESI) interface for connecting to hotel card key , occupied/unoccupied sensor or lighting interlock signal ․Optional digital input (DI) contact for connecting to room’s door/window contact to save energy ․Adjustable unoccupied setpoints for heating and cooling mode control ․Optional settable countdown Timer (0 to 24 hours) function to stop control output when time expires ․Optional sleep mode function for raising 2℃ temperature setpoint in 2 hours when enable ․Non-volatile memory (EEPROM) retains user settings during power loss ․Each button and Energy Saving lockable ․oC or oF and relative humidity (%RH) displays ․Control off output when system at “OFF” status ․Maximum and minimum set-point limits settable |
TBB700-H Series-BTL Certified BACnet® MS/TP Digital Modulating Control Thermostat with Both Temperature and Humidity Displays ․BTL certified BACnet MS/ TP, RS-485 open protocol communication with complete baud rate selections ․Effective run time accumulation for system reading/resetting ․The fan speed can be operated in the mode of auto changeover or manual selected continuous mode. ․Room temperature or setpoint temperature selectable for normal display ․Full configurable parameters such as switching differential, cycle time, and etc. ․Proportional plus integral (PI) algorithm applied to modulating control and/or floating control ․0(2) to 10 Vdc or 10 to 0(2) Vdc control signal output selectable for direct / reverse acting output ․Optional multi-stage on/off control outputs ․Minimum Cycle/ On/ Off time settable ․Optional Remote sensor (RS) input interface for connecting to remote temperature sensor ․Optional Energy Saving input (ESI) interface for connecting to hotel card key , occupied/unoccupied sensor or lighting interlock signal ․Optional extra digital input for Window/ Door open detection to save energy ․Adjustable unoccupied setpoints for heating and cooling mode control ․Optional settable countdown Timer (0 to 24 hours) function to stop control output when time expires ․Optional sleep mode function for raising 2℃ temperature setpoint in 2 hours ․Non-volatile memory (EEPROM) retains user settings during power loss ․User’s buttons and Energy Saving lockable ․oC or oF and relative humidity (%RH) displays ․Control off output when system at “OFF” status ․Maximum and minimum set-point limits settable | TBM700-H Series-Modbus Digital Modulating Control Thermostat with Both Temperature and Humidity Displays ․RS-485 Modbus/ RTU open protocol communication with complete baud rate and parity selections ․Effective run time accumulation for system reading/resetting ․The fan speed can be operated in the mode of auto changeover or manual selected continuous mode. ․Room temperature or setpoint temperature selectable for normal display ․Full configurable parameters such as switching differential, cycle time, and etc. ․Proportional plus integral (PI) algorithm applied to modulating control and/or floating control ․0(2) to 10 Vdc or 10 to 0(2) Vdc control signal output selectable for direct / reverse acting output ․Optional multi-stage on/off control outputs ․Minimum Cycle/ On/ Off time settable ․Optional Remote sensor (RS) input interface for connecting to remote temperature sensor ․Optional Energy Saving input (ESI) interface for connecting to hotel card key , occupied/unoccupied sensor or lighting interlock signal ․Optional extra digital input for Window/ Door open detection to save energy ․Adjustable unoccupied setpoints for heating and cooling mode control ․Optional settable countdown Timer (0 to 24 hours) function to stop control output when time expires ․Optional sleep mode function for raising 2℃ temperature setpoint in 2 hours ․Non-volatile memory (EEPROM) retains user settings during power loss ․User’s buttons and Energy Saving lockable ․oC or oF and relative humidity (%RH) displays ․Control off output when system at “OFF” status ․Maximum and minimum set-point limits settable |
TBS700-H Series-Full Configurable Modulating Control Thermostats With Both Temperature and Humidity Displays ․The fan speed can be operated in the mode of auto changeover or manual selected continuous mode. ․Room temperature or setpoint temperature selectable for normal display ․Full configurable parameters such as switching differential, cycle time, and etc. ․Proportional plus integral (PI) algorithm applied to modulating control ․0(2) to 10 Vdc or 10 to 0(2) Vdc control signal output selectable for direct / reverse acting output ․Optional multi-stage on/off control outputs ․Minimum Cycle/ On/ Off time settable ․Optional Remote sensor (RS) input interface for connecting to remote temperature sensor ․Optional Energy Saving input (ESI) interface for connecting to hotel card key , occupied/unoccupied sensor or lighting interlock signal ․Optional digital input (DI) contact for connecting to room’s door/window contact to save energy ․Adjustable unoccupied setpoints for heating and cooling mode control ․Optional settable countdown Timer (0 to 24 hours) function to stop control output when time expires ․Optional sleep mode function for raising 2℃ temperature setpoint in 2 hours when enable ․Non-volatile memory (EEPROM) retains user settings during power loss ․User’s buttons and Energy Saving lockable ․oC or oF and relative humidity (%RH) displays ․Control off output when system at “OFF” status ․Maximum and minimum set-point limits settable |
TBB500-H Series-BTL Certified BACnet Full Configurable Floating Control Thermostats With Both Temperature and Humidity Displays ․BACnet MS/ TP, RS-485 open protocol communication with complete baud rate selections ․For 2-Pipe or 4-Pipe Fan-Coil Unit, AHUs, or pressure dependent VAVs application of floating control. ․Advanced time proportional plus integral (PI) algorithm applied to floating control for different stroke times ․The 1- to 3-fan speed can be operated in the mode of auto changeover or manual selected continuous mode. ․Full-fledged configurable parameters such as switching differential, cycle time, and etc to provide customized control requirements. ․Effective run time accumulation for system reading/resetting ․Room temperature or setpoint temperature selectable for normal display ․Optional Remote sensor (RS) input interface for connecting to remote temperature sensor ․Optional Energy Saving input (ESI) interface for connecting to hotel card key , occupied/unoccupied sensor or lighting interlock signal ․Optional extra digital input (DI) interface for connecting to hotel window/door open detection contact for energy saving control ․Adjustable unoccupied setpoints for heating and cooling mode control ․Optional settable countdown Timer (0 to 24 hours) function to stop control output when time expires ․Non-volatile memory (EEPROM) retains user settings during power loss ․Minimum open/ close and on/ off time adjustments ․User’s buttons and Energy Saving lockable ․oC or oF and relative humidity (%RH) displays ․Control off output when system at “OFF” status ․Maximum and minimum set-point limits settable | TBM500-H Series-Modbus Full Configurable Floating Control Thermostats With Both Temperature and Humidity Displays ․RS485 Modbus/RTU protocol communication with complete baud rate and parity selections ․For 2-Pipe or 4-Pipe Fan-Coil Unit, AHUs, or pressure dependent VAVs application of floating control. ․Advanced time proportional plus integral (PI) algorithm applied to floating control for different stroke times ․The 1- to 3-fan speed can be operated in the mode of auto changeover or manual selected continuous mode. ․Full-fledged configurable parameters such as switching differential, cycle time, and etc to provide customized control requirements. ․Effective run time accumulation for system reading/resetting ․Room temperature or setpoint temperature selectable for normal display ․Optional Remote sensor (RS) input interface for connecting to remote temperature sensor ․Optional Energy Saving input (ESI) interface for connecting to hotel card key , occupied/unoccupied sensor or lighting interlock signal ․Optional extra digital input (DI) interface for connecting to hotel window/door open detection contact for energy saving control ․Adjustable unoccupied setpoints for heating and cooling mode control ․Optional settable countdown Timer (0 to 24 hours) function to stop control output when time expires ․Non-volatile memory (EEPROM) retains user settings during power loss ․Minimum open/ close and on/ off time adjustments ․User’s buttons and Energy Saving lockable ․oC or oF and relative humidity (%RH) displays ․Control off output when system at “OFF” status ․Maximum and minimum set-point limits settable |
TBS500-H Series-Full Configurable Floating Control Thermostats With Both Temperature and Humidity Displays ․For 2-Pipe or 4-Pipe Fan-Coil Unit, AHUs, or pressure dependent VAVs application of floating control. ․Advanced time proportional plus integral (PI) algorithm applied to floating control for different stroke times ․The 1- to 3-fan speed can be operated in the mode of auto changeover or manual selected continuous mode. ․Full-fledged configurable parameters such as switching differential, cycle time, and etc to provide customized control requirements. ․Room temperature or setpoint temperature selectable for normal display ․Optional Remote sensor (RS) input interface for connecting to remote temperature sensor ․Optional Energy Saving input (ESI) interface for connecting to hotel card key , occupied/unoccupied sensor or lighting interlock signal ․Optional digital input (DI) contact for connecting to room’s door/window contact to save energy ․Adjustable unoccupied setpoints for heating and cooling mode control ․Optional settable countdown Timer (0 to 24 hours) function to stop control output when time expires ․Non-volatile memory (EEPROM) retains user settings during power loss ․Minimum open/ close and on/ off time adjustments ․User’s buttons and Energy Saving lockable ․oC or oF and relative humidity (%RH) displays ․Control off output when system at “OFF” status ․Maximum and minimum set-point limits settable |
TBB100-H Series-BTL Certified BACnet® MS/TP Digital Multi-stage Control Thermostat with Both Temperature and Humidity Displays ․BTL certifiedBACnet MS/ TP, RS-485 open protocol communication with complete baud rate selections ․Suitable for single to multi-stage On/Off step temperature control applications. ․Adjustable differential and stage band width algorithm applied to multi-stage step controls ․Adjustable minimum staging/ on/ off time ․Effective run time accumulation for system reading/resetting ․Room temperature digital display and user selected temperature setting on demand ․Full configurable parameters such as switching differential, cycle time, and etc. ․Optional Remote sensor (RS) input interface for connecting to remote temperature sensor ․Optional Energy Saving input (ESI) interface for connecting to hotel card key , occupied/unoccupied sensor or lighting interlock signal ․Optional extra digital input (DI) interface for connecting to hotel window/door open detection contact for energy saving control ․Adjustable unoccupied set-point for heating and cooling mode control ․1- to 3-fan speed can be operated in the mode of auto changeover or manual selected continuous mode. ․Optional settable countdown Timer (0 to 24 hours) function to turn off control output when time expires ․Optional sleep mode function for raising 2℃ setpoint temperature in 2 hours when enable ․Non-volatile memory (EEPROM) retains user settings during power loss ․User’s buttons and Energy Saving lockable ․oC/ oF and %RH displays ․Control off output when system at “OFF” status ․Maximum and minimum set-point limits settable | TBM100-H Series-Modbus Digital Multi-stage Control Thermostat with Both Temperature and Humidity Displays ․RS485 Modbus/RTU open protocol communication with complete baud rate and parity selections ․Suitable for single to multi-stage On/Off step temperature control applications. ․Adjustable differential and stage band width algorithm applied to multi-stage step controls ․Adjustable minimum staging/ on/ off time ․Effective run time accumulation for system reading/resetting ․Room temperature or set-point temperature display selectable on demand ․Full configurable parameters such as switching differential, cycle time, and etc. ․Optional Remote sensor (RS) input interface for connecting to remote temperature sensor ․Optional Energy Saving input (ESI) interface for connecting to hotel card key , occupied/unoccupied sensor or lighting interlock signal ․Optional extra digital input (DI) interface for connecting to hotel window/door open detection contact for energy saving control ․Adjustable unoccupied set-point for heating and cooling mode control ․1- to 3-fan speed can be operated in the mode of auto changeover or manual selected continuous mode. ․Optional settable countdown Timer (0 to 24 hours) function to turn off control output when time expires ․Optional sleep mode function for raising 2℃ setpoint temperature in 2 hours when enable ․Non-volatile memory (EEPROM) retains user settings during power loss ․User’s buttons and Energy Saving lockable ․oC/ oF and %RH displays ․Control off output when system at “OFF” status ․Maximum and minimum set-point limits settable |
TBS100-H Series-Full Configurable Digital Multi-stage Thermostats With Both Temperature and Humidity Displays ․Suitable for single to multi-stage On/Off control applications. ․Adjustable differential and stage band width algorithm applied to multi-stage step controls ․Adjustable minimum staging/ on/ off time ․Room temperature digital display and user selected temperature setting on demand ․Full configurable parameters such as switching differential, cycle time, and etc. ․Optional Remote sensor (RS) input interface for connecting to remote temperature sensor ․Optional Energy Saving input (ESI) interface for connecting to hotel card key , occupied/unoccupied sensor or lighting interlock signal ․Optional extra digital input (DI) interface for connecting to hotel window/door open detection contact for energy saving control ․Adjustable unoccupied set-point for heating and cooling mode control ․1- to 3-fan speed can be operated in the mode of auto changeover or manual selected continuous mode. ․Optional settable countdown Timer (0 to 24 hours) function to turn off control output when time expires ․Optional sleep mode function for raising 2℃ setpoint temperature in 2 hours when enable ․Non-volatile memory (EEPROM) retains user settings during power loss ․User’s buttons and Energy Saving lockable ․oC or oF and relative humidity (%RH) displays ․Control off output when system at “OFF” status ․Maximum and minimum set-point limits settable |